We make use of the Flue Gas Analyzer which is a calibrated Electronic Instrument that measures the concentration of various gases emitted by the manufacturing units. Emitted gas samples are collected from the testing port opening of the chimney and processed through the Flue Gas Analyzer to measure the concentrations of Excess Air, Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Oxides of Sulphur (SOx) and Nitrogen (NOx), and flue gas temperature. The analyzer detects any deviations from the optimal range for a given combustion system and provides information to adjust the burners for optimum combustion.
We recommend that the Flue Gas Analysis test be undertaken once every 6 months to ensure effective and optimal functioning of the combustion system. Our trained service specialists will perform the test in the presence of your authorized personnel. There will be zero downtime during the analysis, and a report will be provided to you within 7 days.